Importance of Flow Measurement
We assist you in energy management

Compressed air and inert gases, such as helium, argon, nitrogen, and others, are very expensive. For example, the cost of compressed air is 8-10 times that of electricity, and the cost of industrial gases can be several times higher than that

Factors such as machine wear, leaks, low system energy conversion, fluctuations in production load, and unreasonable system structure or configuration can lead to much more energy being consumed than is actually needed, resulting in significant waste

Through continuous monitoring, you can anticipate issues and ensure that your system always meets your business needs

Our flow meters provide you with precise data at every location, such as instantaneous flow, total gas consumption, etc., allowing you to quickly identify high-consumption areas, leaks, inefficient usage, and overdue maintenance. This helps you save money and energy, significantly reducing gas costs

ABUIABAEGAAg4IWHuQYotMGZ_Qcwng44ggg
Our Flow Meter
Pitot Tube Flow Meter
Thermal Mass Flow Meter
Vortex Flow Meter
Other Flow Meter
F201x-W Pitot Tube Flow Meter
Product Advantages: Anti-pollution; Online Auto-calibration; Smart Terminal; Data Logging
Measurement Range: 5 … 300 Nm/s
Turndown Ratio: 1:60
F202x OEM Pitot Tube Flow Meter
Product Advantages: Smart Terminal; Data Logging
Measurement Range: 5 … 300 Nm/s
Turndown Ratio: 1:60
F211x Insert Type Thermal Mass Flow Meter
Product Advantages: Ultra-wide flow measuring range
Measurement Range: 0(0.1) … 250 Nm/s
Turndown Ratio: 1:2500
F211x-Ex Insert Type Explosion-proof Thermal Mass Flow Meter
Product Advantages: Passed national explosion-proof certification
Measurement Range: 0(0.1) … 250 Nm/s
Turndown Ratio: 1:2500
F212x Pipe Type Thermal Mass Flow Meter
Product Advantages: Ultra-wide flow measuring range
Measurement Range: 0(0.1) … 250 Nm/s
Turndown Ratio: 1:2500
F212x-Ex Pipe Type Explosion-proof Thermal Mass Flow Meter
Product Advantages: Passed national explosion-proof certification
Measurement Range: 0(0.1) … 250 Nm/s
Turndown Ratio: 1:2500
F221x Insert  Type OEM Type Thermal Mass Flow Meter
Product Advantages: Ultra-wide flow measuring range
Measurement Range: 0(0.1) … 250 Nm/s
Turndown Ratio: 1:2500
F222x Pipe Type OEM Type Thermal Mass Flow Meter
Product Advantages: Ultra-wide flow measuring range
Measurement Range: 0(0.1) … 250 Nm/s
Turndown Ratio: 1:2500
F235x Compact Thermal Mass Flow Meter
Product Advantages: Ultra-wide turndown ratio
Measurement Range: 0.02 … 3000 SLM
Turndown Ratio: 1:100
F231x-VS New-generation Anti-vibration Steam Vortex Flow Meter
Product Advantages: High temperature resistance and explosion proof certification
Measurement Range: 1.5 m/s ... 80 m/s (Gas / Steam, actual velocity); 0.15 m/s ... 8 m/s (Liquid)
Turndown Ratio: 1:53
F231x-V New-generation Anti-vibration Vortex Flow Meter
Product Advantages: The low measuring limit of gas flow rate can reach 1.5 m/s
Measurement Range: 1.5 m/s ... 80 m/s (Gas, actual velocity); 0.15 m/s ... 8 m/s (Liquid)
Turndown Ratio: 1:53
F231x OEM Anti-vibration Vortex Flow Meter
Product Advantages: Dual vortex sensors
Measurement Range: 4.0 m/s ... 60 m/s/
Turndown Ratio: 1:15
F203B New-generation Clamp-type Ultrasonic Liquid Flow Meter
Product Advantages: Accurate measurement at low flow rates
Measurement Range: 0.03 m/s … ±12 m/s
Turndown Ratio: 1:400
F232x New-generation Liquid Electromagnetic Flow Meter
Product Advantages: Excellent Anti-corrosion Capability; Range Modifiable Online
Measurement Range: 0.7 m/s ... 7 m/s  (Customizable)
Turndown Ratio:
F233x Turbine Liquid Flow Meter
Product Advantages: High Accuracy Measurement; Intelligent Low-power Cuicuit
Measurement Range: Please refer to "Measuring Range"
Turndown Ratio: 1:6 / 1:10
Flow Meter Selection Recommendation

Model

F201x-W
Pitot Tube Flow Meter

F211x
Thermal Gas Mass
Flow Meter

F212x
Thermal Gas Mass
Flow Meter

F231x-V
Vortex Flow Meter

Appearance

201@3x.png

211@3x.png

212@3x.png

231@3x.png

Harsh Working Condition




Install under Pressure

Clean Gas




Unclean Gas




Diameter > DN300



Diameter ≤ DN32




Low Flow Application:
Branch Pipe & Single Unit Gas
Consumption



Vacuum Flow Measurement
Clean Working Conditon



Blower Flow Measurement
(Low Pressure & Large Pipe)



Steam Measurement









Low Flow Measurement (Leak Monitoring)
High Flow Measurement
Optimal Use Range
ABUIABAEGAAg-OX8pQYovZfhggQwsBg4nAI
F231x-V
F201x-W
F211x/F212x/F235x
Do you want to choose the most suitable flow meter for your on-site conditions? Our pre-sales engineers provide one-on-one technical support. Feel free to contact us!
Technical Q&A
What are the Common Flow Meter on the Market?

Differential Pressure Type: Pitot Tube Flow Meter; Orifice Flow Meter; Sonic Nozzle Flow Meter;

Positive Displacement: Roots Flow Meter;

Mass Flow: Thermal Mass Flow Meter; Coriolis Mass Flow Meter;

Velocity Type: Ultrasonic Flow Meter; Vortex Flow Meter; Turbine Flow Meter.

Advantages and Disadvantages of Pitot Tube Flow Meter

Product Advantages:

IInsertion structure allows for installation and maintenance under pressure without stopping air flow, reducing construction costs; Can be used for DN40~600, covering a wide range of pipe diameters, allowing for ample inventory compression; Strong resistance to vibrations and electromagnetic interference; Wide measuring range, with a minimum limit of 5 Nm/s and a 1:60 turndown ratio; Almost no pressure loss, promoting energy efficiency.

Product Disadvantages:
Pressure tap is prone to blockages; Multiple diameter usage with center-point measurement requires accurate mathematical flow models; Zero-point and linearity of differential pressure sensors will experience thermal drift and time drift with changing ambient conditions.
Advantages and Disadvantages of Insert Thermal Mass Flow Meter

Product Advantages:

The plug-in structure can be installed and maintained under pressure without stopping the gas flow, and the construction cost is low. The plug-in installation does not require pipe cutting and docking, and the complete straight pipe section can be retained. It is universal for all pipe diameters in the range of DN25~600, which greatly reduces inventory. It is not afraid of vibration and electromagnetic interference. The measuring range is the widest among all flow meters, with a lower limit of up to 0.1 Nm/s and a turndown ratio of 1:2500. There is almost no pressure loss, which is beneficial to energy saving.

Product Disadvantages:
Afraid of contamination and condensation; universality for multiple pipe diameters plus center point measurement requires an accurate flow mathematical model; the thermal measurement principle is highly nonlinear and requires an accurate calibration algorithm; the traditional thermal flow meter circuit will produce zero-point drift under different operating temperatures.
Advantages and Disadvantages of Vortex Flow Meter

Product Advantages:

It has the strongest anti-pollution ability among the three flow meters and is suitable for harsh working conditions; it is not affected by gas type and gas composition, and the measurement is stable and reliable; it has good linearity and is relatively easy to calibrate and produce; it is the best choice for steam measurement: it has the smallest pressure loss, a wider measurement range than the orifice flow meter, and higher accuracy.

Product Disadvantages:
It has weak resistance to vibration and electromagnetic interference. It has the narrowest turndown ratio and is prone to miss measurements at low flow rates. It needs to stop the gas flow and cut the pipe for installation, which has high construction costs and troublesome maintenance. Since it needs to cut the pipe for docking, centering errors or inconsistent pipe diameters will damage the straight pipe section and cause measurement errors. It has the largest pressure loss among the three flow meters.
Fix Instruments (Shenzhen) Co., Ltd.
We are very honored that you found us. Our engineers continuously test and improve product performance under harsh working conditions to ensure that you receive products with the quality we promise!
Tel: +86-180-2871-3029
Follow Us
Contact Us
Main Products

Fax: 0755 2370 4863
Email: osales@fix-instruments.com
Add.: 2/F, Middle Block, Building B, TG Science Park,
        No. 2 Luozu Industrial Avenue, ShiYan Subdistrict,
        Baoan District, Shenzhen, GuangDong, China